IFESS wishes to provide links that would assist the visitor to our site to find associated societies, research institutions, products and services related to electrical stimulation. IFESS does not warrant or endorse the information or organizations provided in these links in any way, we merely want to provide a mechanism for acquiring information that may be useful to the user. SocietiesAcademic Research InstitutesHospitals and ClinicsCompanies / Commercially Available Products - (Yellow Pages Listings)Charities and Non-Profit OrganizationsJob PostingsPositions WantedHow to Submit
Material to the
|
|
Name of Device or System
|
|
|
Available in what countries; Names of representatives, sales offices, distributors
|
|
|
Regulatory Approval Status and list of approving agencies
|
|
|
Third party payer coverage
|
|
|
Manufacturer Name, Address and Contact Information
|
|
|
Cost per Device or System
|
|
|
Application: e.g. Multi-purpose clinical device. Explain briefly the patient population and treatment or functional objective
|
|
|
Type: Cutaneous, Percutaneous, Implanted
|
|
|
Description of Stimulation Waveform (include all relevant parameters and their controllable range; e.g. 1-1000pps, 10-1000mS active phase duration; 0-100mA applied to 1K Load; capacitive or inductive coupling; ramp time;
|
|
|
Number of Channels; Describe independent control of each channel
|
|
|
External trigger: Handswitch, footswitch, other.
|
|
|
Open or Closed Loop Control; Specify measure[s] if closed loop
|
|
|
Power source: Battery or wall plug; Indicate source required
|
|
|
Size and Weight
|
|
|
Electrode Options
|
|
|
Compliance Monitor; Please describe ability to interrogate device to determine use
|
|
Table 2 - EMG Feedback Properties (if present in device or system)
|
Electrode Options: Cutaneous or intramuscular and description. Can ES be provided through the EMG electrodes?
|
|
|
Filter Options:
|
|
|
Sampling Rate:
|
|
|
Quantification of EMG signal:
|
|
|
Method of triggering collection of EMG signal:
|
|
|
Modulation of EMG feedback: Describe the following as appropriate: Audio:
Visual display:
Threshold:
Delay in feedback:
Other:
|
|
|
Interface to control electrical stimulation device:
|
|
|
If EMG feedback requires the use of an additional device (for example, a feedback device connected to a stimulator), describe size, weight and power for EMG Feedback device:
|
|
|
If the purchase of EMG Feedback capability is an option feature, what is the additional cost of purchasing the ES and EMG Feedback system?
|
|
|
Send mail to
paul.meadows ifess.org with
questions or comments about this web site.
|