Muscle
Fatigue During Intermittent Stimulation,
Using
Catch-like Property; An Animal Study
H.
Ito*, Y. Shimada**, E. Itoi*, M. Kawatani***T. Matsunaga**, T. Minato *,
T.
Sakuraba*, M. Sato**, S. Chida**, K. Hatakeyama**, K. Iizuka****
*Department
of Orthopedic Surgery, Akita University School of Medicine
2.
Methods
Ten
adult male Wistar rats with average body weight of 277.3g were used in these
experiments. Each rat was deeply anesthetized with an intraperitoneal injection
of pentobarbital sodium (40mg/kg). The isometric force was measured for the
medial gastrocnemius muscle of the right hindlimbs. After opening the popliteal
fossa, the sciatic nerve was carefully exposed and the common peroneal nerve
was cut to eliminate the influence of the ankle dorsiflexion muscles. To
protect the muscles from arefaction, the muscles were covered with a mineral
oil. A drive electrode, made from silver chloride, with a 5-mm distance between
the poles, was placed at the sciatic nerve in the middle thigh level. The
distal tendon of the medial gastrocnemius muscle was attached to an isometric
force transducer. The femur was secured to a rigid fixator to ensure no limb
movement during testing. Throughout the experiment, the muscle was kept at the
natural length using the resistance of 1N (Fig. 1). The medial gastrocnemius
muscle was stimulated for 4 seconds with negative square waveforms, with a
pulse width of 0.2ms and an amplitude of –4V. The stimulation cycle was set at
4 sec. on / 15 sec. off. CFT with 20Hz was initially delivered in 5cycles,
until the muscle was potentiated. After potentiation, CFT with 20Hz, and CIT
that begins with one 10-ms interpulse interval (doublet) followed by CFT, were
delivered alternately (Fig. 2). Maximal contraction force was measured by the
force transducer.
% of initial peak force was used to
assess muscle fatigue. % of initial peak force was calculated by the formula: %
of initial peak force (%) = Tt / Ti Where Ti = peak torque in the period of
initial 4 seconds of stimulation and Tt = peak torque in the period of 4
seconds of stimulation at t cycles from initial stimulation. The data are
reported as mean values ± standard deviation (SD). All data were analyzed
statistically using a repeated measures analysis of variance (ANOVA). Criterion
for significance was a p value < .01.

Fig
1: Schematic
representation of the experimental procedure
Fig 2: Schematic representation of fatigue test. The
CFT with 20Hz and CIT
were delivered alternately.
3. Results
During non-fatigued state, maximum contraction
force of CFT and that of CIT were almost equal. Over time (as a fatigued state
developed), maximum contraction force under CIT came to be greater than maximum
contraction force under CFT. There were statistically significant differences
in muscle fatigue between CIT and CFT (repeated measure ANOVA; p < .0001),
and muscle fatigue was greater under CFT. Final force (% of initial force) was
28.31 ± 7.29% (Mean ± SD) with CFT and 42.82 ± 6.51% with CIT (Fig .3).

Cycles
Fig 3: Time
course of % of initial peak force at during fatigue test.
4. Discussion/Conclusions
From a physiological viewpoint, muscle fatigue has been sub grouped into two types, low frequency fatigue (LFF) and high frequency fatigue (HFF). LFF was characterized by a slow rate of recovery for force-generating ability. On the contrary, HFF was characterized by a subsequent rapid recovery from loss of force-generation ability. So under intermittent stimulation cycles with high frequency, the rest time (off time) has an important role in the recovery from muscle fatigue. Based on these features, Mistuning et al compared muscle fatigue resulting from high frequency stimulation with that resulting from low frequency stimulation during intermittent stimulation. In his study, muscle fatigue was greater at low frequency stimulation than at high frequency stimulation, and the contraction force with high frequency was applicable for prevention of knee buckling under fatigued state. So he suggested that intermittent and high frequency electrical stimulation had advantage for clinical usage in restoration of standing using hybrid FES.
To restore standing-up motion using FES, long-duration stimulation trains were necessary. Nagoya et al analyzed the EMG data from lower extremities and back muscles in twelve healthy subjects and made a program for the restoration of standing-up using FES [6]. During standing-up motion, the duration of activity in the quadriceps muscle was measured. The activity of the quadriceps muscle was found to last throughout most of the stand-up time. The mean stand-up time with hands-assists was 2.6 ± 0.5sec. Based on these results, we selected long-duration stimulation trains for this study.
In our study, muscle fatigue was greater under constant-frequency stimulation than under catch-like inducing stimulation during intermittent electrical stimulation. CIT could get a strong contraction force in the fatigued state. These results suggested that intermittent stimulation using catch-like property might be applicable in the development of clinical usage for functional electrical stimulation.
Future work will find optimal stimulation methods by attempting to set different cycles and by changing the number and frequency of initial bursts.
Muscle fatigue was greater under constant-frequency stimulation than under catch-like inducing stimulation during intermittent stimulation.
Acknowledgment
The authors gratefully acknowledge the
support of Prof. M. Kawatani from the
Department of Physiology, Akita University School of Medicine.
[1]Andrews
BJ, et al. Hybrid FES orthosis incorporating closed loop control and sensory
feedback. J Biomed Eng. 10, 189-195, 1988.
[2]Burke
RE, et al. Catch property in single mammalian motor units. Science. 175,
372-376, 1970
[3]Benton
LA, et al. Functional electrical stimulation: a practical clinical guide. 2nd
ed. Downey (CA): Rancho Los Amigos Rehabilitation Engineering Center, 1981.
[4]Binder-Macleod
SA, et al: Effects of activation pattern on human skeletal muscle fatigue.
Muscle & Nerve. 21, 1145-1152, 1998.
[5]Binder-Macleod
SA, et al: Use of catchlike property of human skeletal muscle to reduce
fatigue. Muscle & Nerve. 14, 850-857, 1991.
[6]Kagaya
H., et al: Restoration and analysis of standing-up in complete paraplegia
utilizing functional electrical stimulation. Arch.Phys.Med. Rehabil. 76,
876-881, 1995.
[7]Matsunaga
T., et al: Muscle fatigue from intermittent stimulation with low and high
fequency electrical pulses. Arch.Phys.Med. Rehabil. 80, 48-53, 1999.